PTQ Q3 2022 Issue

Norm NART

END OF CYCLE PROJECTION TOOL

Determine the remaining time for the Current Cycle. The deactivation slope/slope-uncertainty/Current NART/Target NART is editable by users

EDITABLE PARAMETERS

CALCULATION OUTPUTS Remaining Cycle Length Max Remaining Cycle Length Remaining Cycle Length Min

Deactivation Slope Deactivation Slope Uncertainty

Current NART Target NART

avg current

equation

TransPlus Average Reactor Temperature TransPlus Normalised Average Reactor Temperature

Regression TransPlus Normalised Average Reactor Temperature

y*

*x(months) + [

].r2-0.122

TransPlus Normalised Days on Oil (righty)

NART Projection What-if Tool

Cycle Prediction with NDOO

End of Cycle Projection

Run

Historical Data

Calculation Done

Min.Est.Cycle Length Est.Cycle Length Max.Est.Cycle length

WIT Name TP NART Projection

NART PROJECTION INPUTS

Description

Unit

Min

Max

Base Case

Deactivation Slope

˚C/mo

Deactivation Slope Uncertai...

%

Current NART

˚C

Normalised days on Oil (Months)

mo ˚C

Current NDOO Target NART

Cycle Production with Actual Date

NART PROJECTION INPUTS

Description

Unit

Min

Max

Base Case

End of Cycle Projection with Actual Date

Current NART

˚C

Target NART

˚C

Historical Data Min.Est.Cycle Length Est.Cycle Length Max.Est.Cycle length

Deactivation Slope Uncertai...

%

Deactivation Slope Min

˚C/mo

Figure 4 Transalkylation process in operation

Monitoring the main KPIs enables unit troubleshooting by continuous comparison of actual and normalised per- formances, calculated based on reconciled data using high fidelity models supplied by the process licensor or catalyst

supplier. In addition, an optimisation module targeting aro- matic yield maximisation can be set up (see Figure 3 ). The optimiser will only search within the defined upper and lower boundaries of the weight average inlet temperature,

Absorbers DP (Calculation)

11:11:02

11:11:04

11:11:06

11:11:08

11:11:10

11:11:12

11:11:14

11:11:16

11:11:18

11:11:20

11:11:22

11:11:24

Absorber A (Calculation)

Absorber A (Measured)

Absorber B (Calculation)

Absorber B (Measured)

STEP

Absorbers DP (Calculation) 12 Steps Shift

11:11:02

11:11:04

11:11:06

11:11:08

11:11:10

11:11:12

11:11:14

11:11:16

11:11:18

11:11:20

11:11:22

11:11:24

Absorber A (Calculation)

Absorber A (Measured)

Absorber B (Calc) 12 Steps Shift

Absorber B (Measured) 12 Steps Shift

STEP

Figure 5 Adsorption section in operation

18

PTQ Q3 2022

www.digitalrefining.com

Powered by