Precious metal catalyst sampling: Not a trivial pursuit

bradford cook sabin metal corporation

cherries and the grapes. Now, when we mix and take our core sample, we can see that we have a better chance of accuracy. Best of all, of course, would be to juice the entire thing and separate the seeds, stems, and pits, as we would then be that much closer to molecular uniformity, but that would be very expensive. The point here is that thought must be given to the overall value and difficulty in processing the precious metal-bearing catalyst in order to determine the most appropriate processing method(s). In some cases, organic contamination has become excessive, and thermal treatment can volatilise the carbon, moisture, and ben- zene. Screening can remove spacer balls or other support media and trash. The goal is to have a clean parcel of dry and free-flow- ing catalyst that is both constitutionally did you know? It is not unusual for 8 or 10 MT of catalyst, worth approx. €500,000 at today’s platinum prices, to be valued based on an aliquot of one gram or less uniform (the similarity of each particle) and distributionally uniform (how well-mixed the particles are overall). Blending has been found to be of dubi- ous value when sampling precious metal- bearing catalysts. Much greater success is achieved using a sampling system that uti- lises a multiple aliquot philosophy to achieve statistical precision. Some of the crucial aspects of a top-notch sampling system:

Precious metals are likely among the most recycled substances on earth as their value always seems to make it worth someone’s time and effort to retrieve, regardless of the form they may take. For those whose day- to-day activity does not involve precious metals or the catalyst, let us start with a brief introduction. Many petroleum and petrochemical pro- cesses use catalysts containing precious metals (platinum, palladium, ruthenium, and rhodium, commonly referred to as plati- num group metals, or PGMs) or another val- uable precious metal, rhenium. Whatever their precious metals composition, all PGM and rhenium-bearing catalysts must even- tually be replaced with fresh catalysts (or ‘changed out’) to restore process efficacy or speed up process reactions; typically, this happens every three to five years. The spent catalysts are sent to a precious met- als refiner to determine the value contained and return the precious metals (or the mon- etary equivalent) to the catalyst owner. That Which Truly Matters When it comes to determining the value inside your precious metal spent catalyst asset, what truly matters? In this context, it is not the processing fees or the shipping charges; it is obtaining the correct value for your precious metals. That is quite literally where the money is. At the precious metals reclaimer, this breaks down into six funda- mental service qualities and, like the game, you must have all wedges to ‘win’ ( Figure 1 ): The no-compromise essentials: u Having the technical knowledge and experience to accomplish the job v Following all proper regulatory, environ- mental, and safety rules w Adhering to strict ethical standards The scope of work itself: x The correct weight y A representative sample z An accurate and precise assay. The PGM value determination is made by processing the material, sampling it, and then assaying that sample for the appropri- ate metals. Weight times assay of the sam- ple equals the value. Without correct values for all three of these data points, there is no chance of determining the PGM value. • Weight accuracy is verified on the spot: the customer or their representative witnesses the certified test weights being utilised and checks every scale used for a proper zero at the start • Great attention has been give n to the pre- cision and accuracy of the precious metals assay, and rightly so, but. . .

u The consistent and constant flow of material v The entirety of the lot must go through the system w Draw many small samples in equal amounts at regular intervals x The smaller the device, the smaller the particle size. y The entire sampling system must be thoroughly cleaned before and afterwards. Accuracy AND Precision The difference between accuracy and pre- cision deserves a quick mention here. Many people use these words interchangeably, but they have different meanings in the sampling and lab context. High accuracy is getting close to the cen- tre of the bull’s eye every time (see Figure 2 ). In our lab, this would translate to repeat- edly getting the platinum assay close to correct. High precision is getting a very con- sistent ‘shot group’ on your archery target or a set of assay results that are very close to one another. The high precision/low accu- racy laboratory is, in effect, precisely wrong. In both sampling and assay, we clearly need both accuracy and precision. When creating a sampling system, we can prove accuracy and precision by run- ning the same material (with known con- tent, such as a manufactured standard) through the sampling system three or four dozen times. The 40 or so samples can then go to the lab and see if the results are a) accurate – all very close together, and b) precise – close to the known metal content of the standard material. Achieve both accuracy and precision, and you have a great sampling system. In the analytical lab, every sample that arrives is run multiple times through multi- ple assay methods alongside quality control standards and blanks. Consistent, accu- rate, and precise results must be confirmed before any final numbers are reported commercially. Conclusion The critical nature of the sample is clear: once it has been drawn from the customer lot, any error or mis-step is compounded pro- portionally. Each time the sample is reduced in size, the mistake is multiplied again, which means a larger and larger amount of money is moving in the wrong direction. To find out more about this topic and oth- ers in the world of precious metals, please visit us at www.sabinmetal.com.

Technical know-how

Proper assaying

Accurate weighing

Compliance

Ethical standards

Representative sampling

Figure 1 Wedges

• The best lab in the world is of no use if pre- sented with a poor sample. Let us, there- fore, talk about sampling. To underscore the importance of sample accuracy, please note that eventually, at the analytical stage, one gram or less will become the aliquot. The aliquot is the sam- ple portion being used for analysis. It is not unusual for 8 or 10 MT (metric tonnes) of catalyst, worth approximately €500,000 at today’s platinum prices, to be valued based on an aliquot of one gram or less. Uniformity of the Material to Be Sampled It is in the best interest of all parties to pro- cess the material in question to the highest reasonable level of uniformity before pro- ceeding to sampling. A useful illustration here is a swimming pool full of fruit. Let us picture hundreds of kilos of apples, water- melons, cherries, bananas, and so on fill- ing an Olympic-sized swimming pool, and we need to take an accurate sample. One could mix well, take a long section of PVC pipe, and shove it into this fruit salad to get a core sample, but is this really a represent- ative sample? This is where we should introduce one of the fundamentals of proper sampling: parti- cle size reduction. Using a melon baller, we could reduce everything to the size of the

Precision vs Accuracy

High accuracy Low precision

Low accuracy High precision

High accuracy High precision

Low accuracy Low precision

Contact: sales@sabinmetal.com

Figure 2 Precision vs accuracy

Delegates scored top marks for the 2023 event

TOP AGENDA 93%

NETWORKING 96% of attendees made new industry connections

EXPERT SPEAKERS 100% of delegates said the speaker line-up met or exceeded their expectations

of delegates said the content and topics met or exceeded their expectations

25

Powered by